CL-406-S Residual Chlorine Sensor
It is used for continuous monitoring of residual chlorine content in aqueous solution in drinking water treatment plants, canning plants, drinking water distribution networks, swimming pools, cooling circulating water, water quality treatment engineering and so on.
Messages
Product Parameters
Model |
CL-406-S |
Measuring principle |
Constant voltage method |
Range ability |
0~2.000mg/L(HClO) |
Resolution |
0.001mg/L |
Precision |
±5% or ±0.05mg/L ±0.5℃ |
Calibration function |
Two-point calibration (zero and slope) |
Working pressure |
<0.1MPa |
pH range of the medium |
4~9 pH |
Temperature compensation |
Automatic temperature compensation (Pt1000) |
Signal output |
RS-485 bus, Modbus/RTU protocol |
Material |
POM-Polyoxymethylene, polytef |
Working temperature |
5~50℃ |
Installation mode |
Circulation pool installation |
Dimension |
30×233mm |
Flow speed |
30~60L/h |
Response time |
<30S |
Power supply |
12~24VDC±10% |
Power |
0.2W@12V |
Protection grade |
IP68 |