FUV- 408 Online Full Spectrum Multi-Parameter Sensor

Any substance will absorb light of a specific wavelength. Therefore, by measuring the degree to which these substances absorb specific wavelengths of light, the content of the substance dissolved in water can be accurately measured. The FUV-408 online full-spectrum multi-parameter sensor uses a xenon lamp as a light source, which can emit light of all wavelengths from near ultraviolet to near infrared. It collects full-range spectral information through a micro-fiber spectrometer. In addition, it compensates for the attenuation of the optical path through a specific algorithm and can eliminate the interference of particulate suspended impurities to a certain extent, thereby achieving more stable and reliable measurement. Features: 🟥 No reagents required, no pollution, economical and environmentally friendly Installation is more convenient, and water quality monitoring can be performed online continuously Can measure COD, BOD, TOC, color, turbidity, TP, TN, NHN, nitrate, nitrite and other parameters Automatic compensation for turbidity interference Small drift, fast response, more accurate measurement Excellent stability even for long-term monitoring Maintenance-free, long service life, low cost Digital sensor, RS-485 interface, Modbus/RTU protocol Low power consumption design, anti-interference design
Messages

Product Parameters

model

FUV- 408

Measuring principle

Full spectrum absorption method

Range

COD

Chroma

TOC

Turbidity

BOD

0~

200mg/L

equiv. KHP

0~500Hazen

0~150mg/L

0 ~400NTU

0~150mg/L

Range

TP

TN

NHN

Nitrates

Nitrite

0~15 mg/L

0~100 mg/L

0~80 mg/L

0~15 mg/L

0~10 mg/L

COD

Accuracy

±5%FS

COD

resolution

0.1mg/L

Chromaticityaccuracy

±5%FS

Chroma

resolution

0.1 Hazen

TOC

accuracy

±5%FS

TOC

resolution

0.1mg/L

Turbidityaccuracy

±5%FS

Turbidityresolution

0.1NTU

BODaccuracy

±5%FS

BODresolution

0.1mg/L

TP accuracy

±5%FS

TP resolution

0.1mg/L

TN accuracy

±5%FS

TN resolution

0.1mg/L

NHNAccuracy

±5%FS

NHN

0.1mg/L

 

resolution

 

Nitrate

accuracy

±5%FS

Nitrateresolution

0.01mg/ L

Nitriteaccuracy

±5%FS

Nitriteresolution

0.01mg/ L

Calibration

Spectral calibration

Output signal

RS-485(Modbus/RTU)

Power supply

12VDC

Power

consumption

5W@12V

Workingconditions

0~45℃、<0.1MPa

Storage

temperature

-5~65℃

Protectiongrade

IP68

Installation

Immersion installation

Cable length

5 meters, other lengths can be customized

Wettedmaterial

316L Stainless Steel

Media Material